Dimensions
Product Net Depth / Length:
Technical
Rated Operational Voltage:
Rated Control Supply Voltage (Us):
Rated Control Circuit Voltage (Uc):
Rated Operational Power - In-Line Connection (Pe):
Rated Operational Current - In-Line Connection (Ie):
Service Factor Percentage:
Recommended MS495 70 ... 90
Integrated Electronic Overload:
Adjustable Rated Motor Current Ie:
Starting Capacity at Maximum Rated Current Ie:
0 ... 20 second [unit of time]
1 ... 10 second [unit of time]
Initial Voltage During Start:
Step Down Voltage Special Ramp:
Switch for Inside Delta Connection:
Signal Indication Completed Start Ramp (LED):
Signal Indication Ready to Start/Standby ON (LED):
Signal Indication Running R (LED):
Signal Indication Ramping Up/Down (LED):
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:
Connecting Capacity Main Circuit:
Connecting Capacity Control Circuit:
Rigid 1/2 x 0.75 ... 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 0.75 ... 2.5 mm²
Soft start with voltage ramp
Soft stop with voltage ramp
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Tightening Torque UL/CSA:
Control Circuit 5.3 in·lb
Supply Circuit 5.3 in·lb
Environmental
Operation -25 ... +60 °C
Material Compliance
Conflict Minerals Reporting Template (CMRT):
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA:
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Declaration of Conformity - CCC:
Declaration of Conformity - CE:
Container Information
Package Level 1 Depth / Length:
Package Level 1 Gross Weight:
Classifications
Object Classification Code:
The softstarter PSR85-600-11 has a rated maximum operational current of 85 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
The exact weight of the cargo you've scheduled will be measured at the QUANTUM office. We will send you an email with a payment link if the weight difference is larger than the shipment amount. The payment link email will include the new weight and the difference amount that must be paid. If you have any queries concerning this procedure, please contact our customer support team at +1-905-625-3500.