ABB

    In Stock (13 Available)

    1SFA898203R7000

    The softstarter PSTX30-690-70 has a rated maximum operational current of 30 A with an operating voltage span from 208...690 V AC. The rated control voltage is between 100...250 V AC at 50/60 Hz.


    $1,476.49 $1,230.41 / each
    1
    1SFA898203R7000
    ABB
    FACTORY SEALED
    Add To Cart Buy Now

    • Quality Assurance

      OEM Quality Spare Parts.

    • Secure Shopping

      100% Money Back Guarantee.

    • 30-DAY RETURNS

      30 Days After-sales Return.

    • Worldwide Delivery

      Worldwidely Fast Shipping.


    Dimensions

    Product Net Width:
    150 mm
    Product Net Height:
    314 mm
    Product Net Depth / Length:
    198 mm
    Product Net Weight:
    4.6 kg

    Technical

    Rated Operational Voltage:
    208 ... 690 V AC
    Rated Control Supply Voltage (Us):
    100 ... 250 V AC
    Rated Control Circuit Voltage (Uc):
    24 V DC
    Rated Frequency (f):
    50/60 Hz
    Main Circuit 50 / 60 Hz
    Rated Operational Power - In-Line Connection (Pe):
    (230 V) 7.5 kW
    (400 V) 15 kW
    (500 V) 18.5 kW
    (690 V) 25 kW
    Rated Operational Current - In-Line Connection (Ie):
    30 A
    Rated Operational Power - Inside Delta Connection:
    at 230 V 12.5 kW
    at 400 V 25 kW
    at 500 V 30 kW
    at 690 V 45 kW
    Rated Operational Current - Inside Delta Connection:
    52 A
    Service Factor Percentage:
    100 %
    Overload Protection:
    Built-in electronic overload protection
    Integrated Electronic Overload:
    Yes
    Adjustable Rated Motor Current Ie:
    30 ... 100 %
    Starting Capacity at Maximum Rated Current Ie:
    4xIe for 10s
    Ramp Time:
    1 ... 120 second [unit of time]
    Initial Voltage During Start:
    10 ... 99 %
    Step Down Voltage Special Ramp:
    100 ... 10 %
    Current Limit Function:
    1.5 ... 7.5 xle
    Switch for Inside Delta Connection:
    Yes
    Run Signal Relay:
    Yes
    By-pass Signal Relay:
    Yes
    Fault Signal Relay:
    Yes
    Overload Signal Relay:
    Yes
    Analog Outputs:
    0…10 V, 0…20 mA, 4…20 mA
    Signal Indication Ready to Start/Standby ON (LED):
    Green
    Signal Indication Running R (LED):
    Green
    Signal Indication Protection (LED):
    Yellow
    Signal Indication Fault (LED):
    Red
    Communication:
    Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
    Degree of Protection:
    IP00
    Terminal Type:
    Cable Clamp
    Connecting Capacity Main Circuit:
    Hole Diameter 8.5 mm
    Connecting Capacity Control Circuit:
    Rigid 1 x 2.5 mm²
    Connecting Capacity Supply Circuit:
    Rigid 1 x 2.5 mm²
    Tightening Torque:
    Main Circuit 8 N·m
    Product Main Type:
    PSTX30
    Function:
    Auto phase sequence detection
    Automatic restart
    Current limit
    Current limit ramp
    Dual current limit
    Dynamic brake
    Electricity metering
    Electronic overload Time-to-cool
    Emergency mode
    Event log
    Protection Function:
    Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
    Warning Details:
    Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

    Technical UL/CSA

    Maximum Operating Voltage UL/CSA:
    Main Circuit 690 V
    Tightening Torque UL/CSA:
    Main Circuit 70.8

    Environmental

    Ambient Air Temperature:
    Operation -25 ... +60 °C
    Storage -40 ... +70 °C
    Degree of Protection:
    IP00

    Material Compliance

    Conflict Minerals Reporting Template (CMRT):
    REACH Declaration:
    RoHS Information:
    RoHS Status:
    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
    Toxic Substances Control Act - TSCA:
    WEEE B2C / B2B:
    Business To Business
    WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)

    Certificates and Declarations

    Declaration of Conformity - CCC:
    Declaration of Conformity - CE:

    Container Information

    Package Level 1 Width:
    200 mm
    Package Level 1 Depth / Length:
    282 mm
    Package Level 1 Height:
    388 mm
    Package Level 1 Gross Weight:
    5.6 kg
    Package Level 1 EAN:
    7320500501382
    Package Level 1 Units:
    box 1 piece

    Classifications

    Object Classification Code:
    Q
    ETIM 7:
    EC000640 - Soft starter
    ETIM 8:
    EC000640 - Soft starter
    ETIM 9:
    EC000640 - Soft starter
    eClass:
    V11.0 : 27370907
    UNSPSC:
    39121521

    The exact weight of the cargo you've scheduled will be measured at the QUANTUM office. We will send you an email with a payment link if the weight difference is larger than the shipment amount. The payment link email will include the new weight and the difference amount that must be paid. If you have any queries concerning this procedure, please contact our customer support team at +1-905-625-3500.

    My Rating

    Login to add/edit rating

    You Have To Buy The Product To Give A Review

    All Ratings


    No Ratings Yet
    Quatum First Automation

    Not Getting The Products Which You Are Searching For?

    We currently stock or can Source at a very competitive price 

    Contact Us Today
    Live Chat Support